Single-shot morpho-functional and structural characterization of the left-ventricle in a mouse model of acute ischemia-reperfusion injury with an optimized 3D IntraGate cine FLASH sequence at 7T MR

Anna, Palmisano, Marco, Piccoli, Caterina Beatrice, Monti, Tamara, Canu, Federica, Cirillo, Angela, Napolitano, Laura, Perani, Paola, Signorelli, Davide, Vignale, Luigi, Anastasia, Antonio, Esposito

Magnetic Resonance Imaging |

Preclinical cardiac MR is challenging and time-consuming. A fast and comprehensive acquisition protocol and standardized image post-processing may improve preclinical research, reducing acquisition time, costs and variability of results. In the present study, we evaluated the feasibility of a contrast-enhanced 3D IntraGate steady-state cine sequence (ce-3D-IG-cine) with short acquisition time (11 min) for a single-shot combined characterization of left ventricle (LV) remodeling and infarct size (IS) in a mouse model of acute ischemia-reperfusion injury. Sixteen male C57BL/6N mice underwent 7T cardiac MR (Bruker, BioSpec 70/30) including optimized ce-3D-IG-cine (total scan time 11 min) at day 1, 5 and 28 after surgery. LV end-diastolic volume (EDVMR) and ejection fraction (EFMR) extracted from MR were compared to ones from short-axis (SA-EDVecho, SA-EFecho) and parasternal long-axis (LA-EDVecho, LA-EFecho) echocardiography. IS was manually and semiautomatically segmented from ce-3D-IG-cine using different standard deviation (SD +2, +3, +4, +5, +6 in respect to a reference tissue). Mice were sacrificed at day 28, immediately after imaging. IS at day 28 was compared to injury burden at histology. MR and echocardiographic morpho-functional parameters were compared, as IS from MR and histology. Bland-Altman plots were used to assess the agreement in ischemic burden segmentation. Volumetric and functional parameters measured on ce-3D-IG-cine correlated to the correspondent echocardiographic parameter (EDVMR vs SA-EDVecho: ρ = 0.813; EDVMR vs LA-EDVecho: ρ = 0.845; EFMR vs SA-EFecho ρ = 0.612; EFMR vs LA-EFecho ρ = 0.791; p < 0.001 in all cases). Manually segmented IS strongly correlated with the scar at histology (ρ = 0.904, p < 0.001). A threshold of +3SD showed the highest performance for semiautomatic assessment of IS compared to manual segmentation (ρ = 0.965, p < 0.001), with an overall reproducibility of 73%, and a peak reproducibility of 80% at day 1. The ce-3D-IG-cine sequence, manually or semiautomatically segmented using 3SD threshold, allows fast and comprehensive LV morpho-functional and structural characterization in myocardial ischemia-reperfusion injury model.